- General
- Specifications
TINNED COPPER WIRE (TCW) TO AS/NZS 1125
Applications: | Marine Trailer Wiring, General Purpose Marine Wiring, Lights, Instrumentation |
Conductor: | TINNED COPPER WIRE (TCW) TO AS/NZS 1125 |
Insulation: | RoHS Compliant V90 P.V.C. to AS/NZS 3808 |
Colours: | Red & Black |
Sheath: | RoHS Compliant 5V90 P.V.C. to AS/NZS 3808 |
Sheath Colours: | White |
Packs: | 50, 100 metres – other packs by request |
Specifications
Code | **MM Industry Equivalent |
Nominal Area (mm²) |
CONDUCTOR NO/DIA (mm) |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
*AMP Rating JASO D609 at 30°C |
Electrical Resistance at 20°C (ohm/km) |
Nominal O.D. (mm) |
Mass (kg/100m) |
---|---|---|---|---|---|---|---|---|---|
MWS21602 | 2 | 0.5 | 16/0.2 | 0.5 | 0.6 | 7 | 39 | 3.2 x 5.2 | 2.6 |
MWS21603 | 3 | 1.13 | 14/0.32 | 0.4 | 0.6 | 16 | 16.7 | 3.3 x 5.5 | 4.1 |
MWS22603 | 4 | 1.84 | 23/0.32 | 0.4 | 0.6 | 22 | 10.2 | 3.8 x 6.3 | 6.1 |
MWS26503 | 6 | 4.5 | 57/0.32 | 0.6 | 0.8 | 38 | 4.15 | 5.7 x 9.6 | 14.0 |
* AMP RATING: TO JASO D609 derating factors apply
** MM – is an industry term that identifies cable size and is not CONDUCTOR CROSS SECTION AREA
Derating Factors for Bundling of Single Core Cables | ||||||||
No of Cables |
1
|
2
|
3
|
4
|
5
|
6 to 7
|
8 to 10
|
11 to 12
|
Factor |
1
|
0.8
|
0.7
|
0.6
|
0.55
|
0.5
|
0.45
|
0.4
|
Derating Factors for Ambient Temperatures °C | |||||
Temperature |
30
|
40
|
50
|
60
|
70
|
Factor |
1.00
|
0.90
|
0.76
|
0.60
|
0.45
|