V90 PVC INSULATED AND SHEATHED
Applications: | Gas Conversions |
Conductor: | OXYGEN FREE Plain Copper Wire to AS/NZS 1125 |
Insulation: | V90 PVC to AS/NZS 3808 |
Core Colour: | Red |
Sheath: | 5V90 PVC to AS/NZS 3808 |
Sheath°Colour: | Black |
Packs: | 30, 100, metres, other packs by request |
Specifications
Code | * MM Industry Equiv. |
Strand No. / Size |
Nominal Area (mm²) |
**AMP Rating at 30°C |
Insulation Thickness (mm) |
Sheath Thickness (mm) |
Electrical Resistance at 20°C (ohm/km) |
Nominal O.D. (mm) |
Mass (kg/100m) |
---|---|---|---|---|---|---|---|---|---|
ADC11603 | 3 | 14/0.32 | 1.13 | 20 | 0.4 | 0.8 | 16.5 | 3.8 | 2.75 |
ADC12603 | 4 | 23/0.32 | 1.84 | 28 | 0.4 | 0.8 | 10.2 | 4.2 | 3.7 |
ADC14103 | 5 | 36/0.32 | 2.9 | 37 | 0.4 | 0.8 | 6.4 | 4.6 | 4.62 |
ADC16503 | 6 | 57/0.32 | 4.59 | 48 | 0.6 | 0.8 | 4.1 | 5.7 | 7.1 |
* MM is an industry term that identifies cable size and is not CONDUCTOR CROSS SECTION AREA
** AMP RATING: TO JASO D609 derating factors apply
Derating Factors for Bundling of Single Core Cables | ||||||||
No of Cables |
1
|
2
|
3
|
4
|
5
|
6 to 7
|
8 to 10
|
11 to 12
|
Factor |
1
|
0.8
|
0.7
|
0.6
|
0.55
|
0.5
|
0.45
|
0.4
|
Derating Factors for Ambient Temperatures °C | |||||
Temperature |
30
|
40
|
50
|
60
|
70
|
Factor |
1.00
|
0.90
|
0.76
|
0.60
|
0.45
|